Chrysler service bulletin 55111275A: Uneven Climate Control Temperatures

Technical service bulletin 55111275A applies to the Chrysler 200, Chrysler 300 and Chrysler Town and Country. The problem: Uneven Climate Control Temperatures.

A service bulletin (TSB) tells dealers how to diagnose and fix a known issue. Unlike a recall, the repair is usually only free under warranty or a warranty extension. If your vehicle has the symptom, mention bulletin 55111275A to your dealer or mechanic.

Chrysler 200

Service bulletin 55111275A: Airbags, Backup camera and sensors

Issued Jul 2016. NHTSA ID 10221558

Sun Sensor Multi zone Auto Climate Control systems. Left and right outlet temperatures do not match when system is in "sync" . Occupants will experience being cold ( winter time), on either passenger or driver side, even though the temperature setting is the same. Root cause: Suspect sun senors ( PN 55111274AA and 55111275AA). THERE WILL BE NO DTC FOR THE SUN SENSOR active or stored. The issue is diagnosed by using an INCANDESCENT (not LED) shop lamp. Shine the shop lamp on the left side of the sensor, then on the right side of the sensor, while monitoring sensor output with STARSCAN. The reading should change from 0 (or near zero) to about 20 to 40. The important thing is that the left and right readings are the same, and that they change when the lamp is shone on it.

Applies to

Source: manufacturer communications filed with NHTSA. Summaries as published by NHTSA. To see the full bulletin, ask a dealer or your mechanic for bulletin 55111275A.

Updated: Recalls and bulletins updated daily. Complaints through October 29, 2026. Find your vehicle to request alerts