BMW service bulletin B640613: Reduced Airflow After Extended AC Use

Technical service bulletin B640613 applies to the BMW 320i, BMW 328d, BMW 328i and 16 more. The problem: Reduced Airflow After Extended AC Use. It was filed with NHTSA 5 times, for different vehicles or with different text: all are below.

A service bulletin (TSB) tells dealers how to diagnose and fix a known issue. Unlike a recall, the repair is usually only free under warranty or a warranty extension. If your vehicle has the symptom, mention bulletin B640613 to your dealer or mechanic.

BMW 320i

Service bulletin B640613: Equipment and accessories

Issued Nov 2021. NHTSA ID 10205068

Customer may complain of reduced air flow when the air conditioning system is operated for an extended time, usually longer than 30 minutes.

Applies to

Service bulletin B640613: Equipment and accessories, Electrical system, Engine and cooling

Issued Dec 2020. NHTSA ID 10186889, 10186227, 10147832

A/C Cooling: Intermittent Reduction of Air Flow. Customer may complain of reduced air flow when the air conditioning system is operated for an extended time, usually longer than 30 minutes. INFORMATION Possibility of reproducing this situation is improved by the following conditions – High outside ambient temperature – High humidity Note: It is very difficult to duplicate this issue. The fault may be reproduced under the following conditions: • Air-conditioning system switched on – Driving Experience switch NOT set to Eco Pro – Slower fan speeds – Temperature setting below 68°F (20°C) ? Trip duration at least 30 minutes – Outside temperature above 68°F (20°C) NOTE: After parking the vehicle or switching off the air-conditioning system for at least 20 minutes, the symptom disappears (ice melts off evaporator and puddles under the car from the A/C drains.). Evaporator starts to freeze up due to the position of the evaporator temperature sensor.

Applies to

Service bulletin B640613: Equipment and accessories

Issued Aug 2019. NHTSA ID 10165263

A/C COOLING: INTERMITTENT REDUCTION OF AIR FLOW This Service Information Bulletin (Revision 9) supersedes SI B64 06 13 dated June 2017. Customer may complain of reduced air flow when the air conditioning system is operated for an extended time usually longer than 30 minutes. The evaporator starts to freeze up due to the position of the evaporator temperature sensor.

Applies to

Service bulletin B640613: Equipment and accessories

Issued Jun 2017. NHTSA ID 10146718

A/C Cooling: Intermittent Reduction of Air Flow What is new The date in repair procedure and warranty section has been changed for vehicles produced to September 30, 2013 and from October 1, 2013.. Customer may complain of reduced air flow when the air conditioning system is operated for an extended time, usually longer than 30 minutes. INFORMATION Possibility of reproducing this situation is improved by the following conditions: High outside ambient temperature High humidity Note: It is very difficult to duplicate this issue. The fault may be reproduced under the following conditions: Air-conditioning system switched on Driving Experience switch NOT set to Eco Pro Slower fan speeds Temperature setting below 68F (20C) Trip duration at least 30 minutes Outside temperature above 68F (20C) NOTE: After parking the vehicle or switching off the air-conditioning system for at least 20 minutes, the symptom disappears (ice melts off evaporator and puddles under the car from the A/C drains). Evaporator starts to freeze up due to the position of the evaporator temperature sensor.

Applies to

Service bulletin B640613: Equipment and accessories

Issued May 2015. NHTSA ID 10147153

A/C Cooling: Intermittent Reduction of Air Flow. The customer may complain of reduced air flow when the air conditioning system is operated for an extended time, usually longer than one hour. The complaint can vary due to one or more of the following variables: • High outside ambient temperature – Too much humidity – A/C temperature and fan settings set too low for too long Note: It is very difficult to duplicate this issue due the required outdoor weather conditions and length of driving time needed. CAUSE Evaporator starts to freeze up due to the position of the evaporator temperature sensor

Applies to

Source: manufacturer communications filed with NHTSA. Summaries as published by NHTSA. To see the full bulletin, ask a dealer or your mechanic for bulletin B640613.