MINI service bulletin SIM-17-02-07: Cooling Fan Runs After Shutdown

Technical service bulletin SIM-17-02-07 applies to the MINI Cooper. The problem: Cooling Fan Runs After Shutdown.

A service bulletin (TSB) tells dealers how to diagnose and fix a known issue. Unlike a recall, the repair is usually only free under warranty or a warranty extension. If your vehicle has the symptom, mention bulletin SIM-17-02-07 to your dealer or mechanic.

MINI Cooper

Service bulletin SIM-17-02-07: Engine and cooling

Issued Dec 2007. NHTSA ID 10032985

Mini: electric cooling fan runs after engine is shut off. After the engine is shut off, the electric cooling fan continues to run. Due to the operating strategy of the dme, the electric cooling fan may continue to run after the engine is shut off in two different scenarios. Engine coolant temp reaches 108 degrees celsius (due to heat soak), cooling fan will activate til coolant temp drops below 105 degrees celsius. Fan will run to assist the auxiliary water pump, which is used to cool turbo charger after engine shut down. No model years listed.

Applies to

Source: manufacturer communications filed with NHTSA. Summaries as published by NHTSA. To see the full bulletin, ask a dealer or your mechanic for bulletin SIM-17-02-07.

Updated: Recalls and bulletins updated daily. Complaints through October 29, 2026. Find your vehicle to request alerts