2003 Ford Taurus windows, mirrors and visibility problems

191 owner complaints to NHTSA in this area. Showing 101–120, newest first.

  1. Reported Jan 2008, 41,000 miles

    My passenger side leaks onto the floor and now the blower has been ruin due to the water that floods in during the rain storms.

    NHTSA complaint 10214539

  2. Reported Jan 2008

    In 2003 tuarus the blower motor and resistor was replaced due to failure from water from ac line. This did not allow ac/heater/defroster fan to function. On highway windows fogged up to zero visability traveling from nc to fl when cold. Fortunitly no accident. Ford is a ware of problem and knows the fix but when I first took car in blower worked and it cost $200.00 for just a check. Ford forum let me know others having problem too and how to fix by replacing motor blower and resistor. Have old parts which are rusted from water damage.

    NHTSA complaint 10213778

  3. Reported Dec 2007, 76,674 miles

    Blower motor went out on my 2003 ford taurus 12/11/07. Repair shop found water in the blower motor cavity. Ford has a kit you can purchase to fix the problem. The entire thing cost me $310. I have found that several customers have had the same problem, the cars should be recalled. Ford has known about this since 7/15/2004 I have a copy of the tsb. I had a switch replaced last winter on the blower motor also.

    NHTSA complaint 10212101

  4. Reported Dec 2007

    I have a 2003 ford taurus. I have found water in the passenger floor board. Over time, the blower fan has stopped working. During research on the internet, I have found that many consumers have had the same problem, and that ford motor company will not repair this obvious defect.

    NHTSA complaint 10211963

  5. Reported Dec 2007, 60,000 miles

    Water leak in windshield dumps water onto the heater blower motor. Called dealership said not covered under warranty, replaced motor once and now must replace again. Believe covered under nhtsa campaign id number 03v087000.

    NHTSA complaint 10211583

  6. Reported Dec 2007

    1. Heavily raining on an hour trip from home. 2. Blower motor for heater stopped working making it unable to see road, traffic, etc and making it freezing in car. Was almost in accident since unable to see. 3. Contacted ford motor co to check recalls. Unable to locate however if you google the problem it appears that there is a defect in the making of this vehicle resulting in damage to the blower motor and sensor. Ford is aware of the problem and has a fix for it however you must pay for the entire cost. Please see the following technical service bulletin tsb 04-15-3. Please also see the following sites for several other complaints: http://www.epinions.com/msg/show_~threads/cat_id_~3/id_~11913/forum_id_~124 http://www.ford-forums.com/ford-taurus/5133-2003-taurus-blower-motor.html http://www.carcomplaints.com/ford/taurus/2003/tsbs.shtml http://wiki.answers.com/q/what_could_cause_the_blower_on_a_2003_ford_taurus_se_to_stop_working http://www.edmunds.com/ford/taurus/2003/consumerreview.html.

    NHTSA complaint 10211107

  7. Reported Dec 2007, 44,500 miles

    Tl contact own a 2003 ford taurus. The contact stated that the heater would not blow. The dealer stated that water inside the blower motor caused the failure. They replaced the blower motor and resistor. The current and failure mileages were 44,500.

    NHTSA complaint 10210869

  8. Reported Dec 2007, 90,600 miles

    I purchased an 03 ford taurus 5 months ago from a ford dealership in pa. Upon the winter season's arrival, I turned on my heat to hear a loud squeaking noise. I took my car to a repair shop where I was told that my blower motor was full of water due to a faulty cowl on the car. I was told that ford was aware of this defect, and that it was semi common, but that ford was not going to cover it under a recall. I was also informed that I would have to pay 500.00 to replace the cowl, the blower motor and a resistor. I called ford to voice my anger about the situation and their response was there were basically not enough complaints and that it was not serious enough to warrant a recall. I disagree. I drive my 1 year old daughter around in the car. I am unable to defrost my windshield because of this, and can often not see out of my winder without rolling them down to let the fog lift off the windows. This is unacceptable. Someone could die as a result of this defect. Ford must be held responsible for this. There was an apparent related recall, but ford still did not and will not take action. 03v087000 <--- recall.

    NHTSA complaint 10210854

  9. Reported Nov 2007, 77,000 miles

    Heater/ac blower only worked on high, water would leak into the passenger side floorboard, now it does not work. There are alot of reports about this for a 2003 ford taurus, please have them recall these and fix them.

    NHTSA complaint 10210132

  10. Reported Nov 2007, 55,000 miles

    Leak on passenger side of 2003 ford tarus, shorted out a/c heater blower motor.

    NHTSA complaint 10210114

  11. Reported Nov 2007, 80,000 miles

    Heater and a/c fan motor suddenly stopped.

    NHTSA complaint 10209507

  12. Reported Nov 2007

    Water dripping into my blower motor.

    NHTSA complaint 10208611

  13. Reported Nov 2007, 46,000 miles

    Tl contact owns a 2003 ford taurus. While driving 35 mph, the blower fan was very loud and the contact was unable to activate the heat. The dealer stated that the a/c heater blower failed due to water leakage. As of november 2, 2007, the dealer had not repaired the vehicle. The contact felt that the recalled part caused the water leakage. The current and failure mileages were 46,000. Updated 12-12-07. The blower motor made a noise and doesn't work at times. Updated

    NHTSA complaint 10207763

  14. Reported Oct 2007

    Car has a faulty windshield installation as described in recall number 03v087000. There is excess wind noise and squeaks and rattles at speed, and the window leaks on the passenger side during heavy rain and in the car wash. The local ford dealerships have been unresponsive, as they claim the vin number does not appear in their system as being eligible for this recall.

    NHTSA complaint 10207415

  15. Reported Oct 2007, 35,000 miles

    I was online checking for an ac/heater blower motor as it only works on high. I discovered a recall for the mercury sable (03v087000) regarding the windshield leaking water onto the passenger side floor. The leak drips on the ac/heater fan motor causing it to short out and to stop operating. I live in wa, I found water on the passenger side floor several times but never found the leak. I see there have been many complaints about this problem. For a temporary repair, I can replace the blower for $500. For a permanent fix, I will also have to replace the windshield, another $500. Thanks ford, you recalled the problem on the mercury sable, why not the taurus.

    NHTSA complaint 10205307

  16. Reported Sep 2007, 29,000 miles

    Heavy rain caused water to appear on front passenger side floor in my 2003 ford taurus. Heater blower motor stopped working at same time. Ford repaired at a cost of $580, including replacing blower. Reference recall #03v087000 and complaint #10184014.

    NHTSA complaint 10204103

  17. Reported Sep 2007, 98,465 miles

    Car was out in the rain. Water leaked into the passenger side floorboard. Had passenger side cowl replaced, rainhat kit installed, and replaced blower motor less than 14,000 miles ago to fix the same issue. Hopefully won't have to replace the blower motor again.

    NHTSA complaint 10203554

  18. Reported Aug 2007, 32,500 miles

    Water leaks onto passenger side floor resulting in interior damage and damage to heater box and blower motor. Dealer replaced cowel at my expense, within 3 months leak returned and dealer wants to remove dash and check heater box, at a minimum expense of $850. Ford has a recall, 03v08700 and tsb 04-15-3 regarding these problems, but wants me to pay for the repairs. I also paid $375 to have the interior cleaned and disinfected after the first repair. I would also like to reference complaint 10184014.

    NHTSA complaint 10200570

  19. Reported Aug 2007, 44,350 miles

    1) normal use. 2) water leaked into heater blower motor of 2003 ford taurus. Blower motor failed. Heater resister also failed. 3) installed new blower motor and resistor. Need to purchase additional parts from tsb 04-15-3 so problem does not repeat. Appears to be poor original engineering that would cause this to occur. There is a related recall, 03v087000 and also a prior complaint 10184014. Thank you!

    NHTSA complaint 10199608

  20. Reported Aug 2007, 53,450 miles

    Tl contact owns a 2003 ford taurus. The blower motor was working intermittently, and on 08/06/2007, it failed completely. The vehicle was taken to the dealer, who stated that the failure was caused by a faulty seal, weather stripping and water that was leaking into the motor. The contact did not want to guess the number of occurrences. The contact did not the current mileage was 53,466 and the failure mileage was 53,450.

    NHTSA complaint 10198970

Complaints are unverified reports from owners, shown as submitted to NHTSA. Personal details are removed by NHTSA.

Other problem areas on the 2003 Ford Taurus

Updated: Recalls and bulletins updated daily. Complaints through October 29, 2026. Request alerts for your vehicle