NHTSA investigation PE10039: Python Lift - Inadvertent Operation

Preliminary evaluation PE10039 (Heil 2006-2009), opened September 30, 2010. Closed December 16, 2010.

A preliminary evaluation is the first stage of an NHTSA defect investigation. An investigation is not a finding that a defect exists.

This investigation led to safety recall 10V590. Recall repairs are free at any authorized dealer.

What NHTSA says

Area: Body and structure. Manufacturer: Heil Company

ODI sent Heil Environmental an Information Request letter on 6 October 2010.After reviewing the letter and subsequent discussions with ODI, Heil decided to issue a safety recall pertaining to 2,201 units built from calendar year 2004 through 2010.They submitted a 573 Defect Report to NHTSA on 22 November 2010.Heil is unaware of any accidents or injuries related to this problem.Therefore this investigation is closed and Heil was excused from answering ODI's information request.

Source: NHTSA Office of Defects Investigation, investigation PE10039, as published by NHTSA.