2003 Ford Taurus: complaints mentioning the cabin air filter

Ford Taurus

What it does

Filter that cleans the air entering the cabin through the heating and air-conditioning system. A routine maintenance item.

Common signs of a problem

  • Weak airflow from the vents
  • Musty smell
  • Windows slow to demist

What owners report

11 owner complaints to NHTSA mention the cabin air filter on the 2003 Ford Taurus.

0 involved a crash, 1 a fire; 0 injuries reported.

Counts are complaints whose text mentions this part. A mention isn't proof the part failed: some complaints mention it in passing, as recently replaced or as working fine. Complaints are unverified owner reports, not confirmed defects.

Cabin Air Filter complaints by model year

'00'01'02'03'04'05'06'07'08'09'10'11'12'13'14'15'16'17'18'19

Owner complaints mentioning the cabin air filter

  1. Reported Aug 2017

    While attempting to shift the vehicle out of park, the gear shifter will not work; specifically the vehicle stays "locked" in the park setting. This has occurred on several occasions and requires me to turn the vehicle off or attempt to "re-set" the brake by applying the brake several times. Additionally, at times the brake lights remain lit after the vehicle has been placed in part and turned off with the driver locking the vehicle after exiting the vehicle. The brake lights remaining lit has caused the battery to completely discharge. To offset this I've had to remove the fuse for the rear brake lights to prevent the battery from discharging. I did have an independent mechanic examine the issue and the mechanic noted the vehicle recall for a 2003 ford taurus for this fault. When I contacted ford I was informed that my vehicle was not included in a lot identified as impacted by the vehicle recall. Specifically the vin from my 2003 ford taurus was not included in the nhtsa campaign number 04v106000 (exterior lighting). This fault first occurred when I was stationed in japan (2004 - 2007) sometime in may of 2004 when the battery discharged to the point that I had to replace the battery; I couldn't jump start the vehicle with the original battery still in the vehicle. The approximate mileage of the vehicle at that time was 3,000 miles. As of today (august 10, 2017) the mileage on the 2003 ford taurus has reached 104,000. Request nhtsa review the records for possible inclusion of the lot for my vehicle for inclusion in this recall. Additionally, wish nhtsa to consider including the lot of my vehicle for inclusion in recall 03v087000 regarding the windshield on my vehicle. I have replaced the cabin air filter and the brake components since purchasing the vehicle, so the recalls addressing those issues are not applicable due to regular maintenance activity.

    NHTSA complaint 11014102

  2. Reported Apr 2016, 132,000 miles

    Tl* the contact owns a 2003 ford taurus. While driving at any speed, the blower motor emitted smoke from under the dashboard on the passenger side of the vehicle. The failure recurred three times. The vehicle was taken to an independent mechanic where it was diagnosed that the resister blower motor was getting damaged with water from the crow and under the air cabin filter where the installation of the cabin air filter. The technician informed the contact that the vehicle need to be taken to a dealer to have the installation replaced. The vehicle was repaired twice; however, the failure recurred. The manufacturer was notified of the failure. The approximate failure mileage was 132,000.

    NHTSA complaint 10860395

  3. Reported Mar 2009, 78,000 miles, fire

    2003 ford taurus wagon. There are serious safety issues that need to be addressed by a recall: water leaking through the cabin air filter area into cabin compartment and seizing and overheating heating resistor and heater blower motor. My ford dealer told me there were no recalls for these problems on my car which is no longer under warranty the water leaking through the cabin air filter area into the cabin compartment in many 2001-3 taurus's have caused their heater blower motors to bind or seize which also burns out the blower resistor. It also eventually causes mold to form in the heater area and under the dampened carpeting. After noting a burning smell several times in my car's cabin after starting my heater fan, my heater defroster blower at first would not work- only to work a bit later-until it finally ceased to work completely. On at least 3 occasions when this happened my vision while driving was severely impeded due to the windshield fogging or icing up, as the dead blower could not defrost it. When I pulled the heater motor and resistor out (still wired) I discovered the cause of the burning smell. When I turned the ignition and fan switch on, the motor seized which caused the resistor to overheat to the point that literally flames were shooting out of the resistor! Luckily I shut the fan off completely when I smelled the burning resistor but it is fortunate the car did not catch on fire. Ford is well are of this problem and has issued a technical service bulletin # 04-15-3 to resolve it. The heater blower motor and resistor must be replaced along with the passenger side windshield cowl (which apparently warps from the sun and heat) and an additional piece of rubber molding installed on the rain hat over the cabin air filter. Additionally an area near the over the cabin air filter must be silicone caulked and some foam insulation removed for proper drainage. I repeat the above are serious safety issues that need to be addressed by a recall.

    NHTSA complaint 10262431

  4. Reported Nov 2008, 92,000 miles

    Tl contact owns a 2003 ford taurus. The contact stated that there should be a splash shield over the cabin filter, located above the heater and near the blower fan. When it rains, water enters and shorts out the resistor or fan. As a result, power is lost. The dealer stated that there was no recall, only service bulletin number 31506. The contact has to purchase a splash shield, which prevents water from seeping down into the blower fan. He stated that this was the third resistor that has been installed since june of 2008 because they continue to short out. The failure mileage was 92,000. Updated 11-25-08 updated 11/26/08.

    NHTSA complaint 10248288

  5. Reported Jul 2008, 108,000 miles

    The a/c - heater blower motor stopped working due to a water leak through the cabin filter into the motor housing. It just stopped working. I took it to ford and they replaced the blower motor, resistor, cowl and new weatherstripping at a cost of $465.01. Since there is a tsb from ford regarding this, I feel that it should be expanded to an all out recall. Ford knows that it is a bad design and ford needs to make good on it's products.

    NHTSA complaint 10232958

  6. Reported May 2008, 84,000 miles

    2003 ford taurus. Blower motor failure due to rain leaking through cabin filter into blower motor. Visibility impaired when windshield then fogged. Water found on passenger floor. Blower and resistor found corroded. Dealer replaced motor, resistor, weatherstrip and defective cowl panel/rain hat. Labor + parts $412. Tsb 03-15-06.

    NHTSA complaint 10228150

  7. Reported Mar 2008

    I was driving my 2003 ford taurus on february 5, 2008, when the blower motor ceased working. I also noticed that there was a water leak on the passenger floor board. When I took my car to goodyear I was told that the water leak caused my blower motor to short out. I understand that this is a mechanical problem and the ford motor company should be responsible for the expense of time lost from work and the following costs: r/r blower motor, $88.00; new blower motor, $110.21; cabinet air filter gasket and blower weatherstrip $27.73; r/r/ cabin filter gasket $70.40 and the costs of installation of the air filter $29.66. The total is $362.82. I am referencing ford's existing recall number, 03v087000 and the complaint of william ford #10184014.

    NHTSA complaint 10221384

  8. Reported Feb 2008, 69,500 miles

    In my 2003 ford taurus water leaks in through the cabin air filter, and basically settles within the housing where the blower is shorting out the blower so the heater doesn't work.

    NHTSA complaint 10218070

  9. Reported May 2007, 16,500 miles

    Rain water leaked into the passenger's compartment via cabin air filter. Water passed through electrical circuits controlling heater and air conditioning systems. A short could occur, possibly igniting a fire. Finally, a puddle will form on the passenger's side floor; the size of the puddle was determined by the amount of rainfall.

    NHTSA complaint 10190850

  10. Reported Sep 2006, 24,300 miles

    2003 ford taurus blower motor stopped working and the windshield fogged up while driving. The problem was water getting into the blower motor area from the cowl area at the cabin filter. Ford knows about this problem and has a tsb fix with a shield and weatherstrip. They tell you about the problem after the water has already caused the problem costing you $300 extra because now you need electrical problems fixed.

    NHTSA complaint 10167953

  11. Reported Jun 2005

    Recently I noticed that there was water leaking into the passenger side floorboard after a heavy rain. A day later, my air conditioning stopped working and I could hear a gurgling sound coming from the system. I took it to the dealership and they told me that they had to install a "rainhat" kit over the cabin filter to prevent water from leaking into the blower motor by way of the cabin filter. Well, the question becomes, why wasn't there anything there before? I went home and did some research and saw that ford issued the following tsb regarding the issue: 14 of 53: visibility:defroster/defogger system:windshield:blower bulletin date: aug 2004water in the blower case or on the passenger side floor, an inoperative climate control blower motor, a motor that operates on high speed only, and/or a blower motor resistor failure. Vehicles built 5/1/2001 to 12/15/2003. Repair was $500. He's my concern. Ford must have known there was design flaw if they (a) posted a tsb and (b) developed a "rainhat" kit to solve this problem. Basically any owner that has a car built between those times will be doomed to pay this repair if they weren't lucky enough to have this fail before the warranty expired. I think that's absurd! I've talked with other owners and they were lucky enough to notice the leak before their blowers went out. The dealerships charged them upwards of $100 to install the "rainhat" kit. If I would have known that this was a problem I would have gladly paid $100 for the kit rather than $500. My dealership even admitted that this happens quite often, but they can't do anything about cost until ford issues a recall. Again, this is a design flaw that needs to be addressed by ford. I don't believe it's right for the consumer to have to pay for a product design flaw. The safety concern here is of course the windshield defogger not being able to operate.

    NHTSA complaint 10125251

Other parts for the 2003 Ford Taurus

Updated: Recalls and bulletins updated daily. Complaints through October 29, 2026. Request alerts for your vehicle